Clean the rollers and separation pad.

Article ID: ART109268 | Date published: 05/11/2015 | Date last updated: 08/16/2015
 

Description

If many pages have been scanned since the last roller cleaning, clean the rollers and separation pad..

Solution

If many pages have been scanned since the last roller cleaning, clean the rollers and/or replace the separation pad.

  1. Open the feed tray.


  2. Open the feeder cover.


  3. Remove any dirt from the scanning glass, separation pad and rollers inside the scanner (parts shown in the figure).

    Use a clean dry cloth to wipe off any dirt on the scanning glass.

    Wipe off any dirt on the rollers with a cloth that has been dampened with water, and then wipe the rollers with a clean soft dry cloth.

    Remove the feeding rollers before cleaning them.


  1. Open the roller cover.


  2. Lift up the roller lock lever, and slide it to the left.


  3. Remove the feed roller.


  4. Once clean, attach the feed roller. Align the notch on the roller with the shaft on the main unit side.


  5. Slide the roller lock lever to the right, insert the left side of the shaft of the feed roller, and then lower the roller lock lever to lock the feed roller into place.


  6. Completely close the roller cover so that it clicks into place.
    Make sure to close the roller cover so that it clicks into place. Failure to securely close the feed cover will cause document feed problems.