User Mode Functions
The following functions are available in the User Mode.
Separation Mode Setting
If double feeding or a paper jam occurs, change to Separation Mode.
HI: Use if friction between sheets is great, and you are feeding documents that are difficult to separate.
Normal: Use this setting normally.
LO: Use when feeding fine document.
Buzzer (Beeper) Control Setting
The beeper ("buzzer") sounds when you press the control panel keys and when a scanning error occurs.
ON2: The beeper sounds when a scanning error occurs, and when a control panel key is pressed.
ON1: The beeper sounds when a scanning error occurs.
OFF: The beeper never sounds.
Double-Feed Control Setting
Select whether double feed detection is enabled when in Count-Only mode. If set to [ON], double feeds are detected during feeding in Count-Only mode. There are two methods of double feed detection, comparing the length of documents and detecting unevenness between documents by ultrasonic sensors, which can be set according to the ISIS/TWAIN driver.
In Count-Only mode, double feed is set to be detected by ultrasonic sensors.
Staple Detection Setting
Select whether staple detection is enabled when the Count-Only mode is enabled.
ON: Detects staples in the Count-Only mode.
OFF: Does not detect staples in the Count-Only mode.
Staple detection during scanning is set with the ISIS/TWAIN driver.
Staple Detection Level Setting
Sets the staple detection sensitivity level.
[1] is the default setting, [2] provides a higher sensitivity, and [0] provides lower sensitivity.
Long Document Mode Setting
You can enable this mode to scan document pages up to 3,000 mm (118.1") long when the Auto Detection page size setting is selected.
ON2: Automatically detects page sizes when scanning documents up to 3,000 mm (118.1") long.
ON1: Automatically detects page sizes when scanning documents up to 1,000 mm (39.4") long.
OFF: Automatically detects page sizes when scanning documents up to 432 mm (17") long.
Feeding a document longer than the maximum detectable page size for Auto Detection causes paper jams, and transport stops.
Continuous Manual Feeding Mode Setting
This mode disables automatic feeding by the pickup roller, so that the loaded document stack must be fed by hand one sheet at a time by the operator.
ON: The pickup roller is disabled.
OFF: Documents are fed by the pickup roller.
Setting the manual feed time for feeding intervals
Set the time that the feed roller will continue to rotate after feeding in a sheaf of documents.
0: 0s
1: 30s
2: 60s
3: 180s
4: 300s
Stand-by Mode Setting
Selects the amount of time (240, 60, or 10 minutes) from when the scanner is last used to when the Stand-by mode is activated.
Display Language Setting
Selects English, Japanese or French for the language to display on the control panel.
EN: English
JP: Japanese
FR: French
Display Contrast Adjustment
Use to adjust display panel contrast.
USB Short Packet Sending
If the scanner does not operate normally when using the USB interface, change this setting to [OFF].
Tray Position Setting
The document feed tray should be set to fit the number of document sheets to be loaded.
0: Up to 500 sheets
1: Up to 300 sheets
2: Up to 100 sheets
Key Repeat Setting
Selects the panel display method.
ON: The panel display scrolls continuously while a key is pressed.
OFF: The panel display scrolls each time a key is pressed.
Key repeat is valid in the following situations.
- When using the Job Function.
- When selecting each of the functions in the User Mode
Total Counter
Displays the lifetime total number of document pages fed by the scanner.
Roller Count
Displays the number of document pages fed since roller installation or replacement (pickup, feed, and retard rollers). Make sure to reset this counter when replacing the rollers.
Imprinter Test
When the optional imprinter is installed, this function executes a test printing of the imprinter.
Auto power OFF function setting
Set the auto power OFF function.
Select ON to enable the auto power OFF function, and if after 4 hours of inactivity, the power turns OFF automatically.