Using the Waveform Monitor on an EOS C700 model

Article ID: ART174790 | Date published: 06/20/2019 | Date last updated: 06/20/2019
 

Description

The camera can display a simplified waveform monitor on the monitoring screen. You can select one of 6 types of monitors and also adjust the waveform amplification.

Solution

Waveform Monitor

Displaying the Waveform Monitor

Press the WFM button
  • The waveform monitor window will appear at the right of the monitoring screen on external monitors connected to one of the MON. terminals or the HDMI OUT terminal.
  • You can also set MENU/EVF  [Assist. Functions]  [Waveform Monitor]  [VIDEO Output] and/or [MON.+HDMI Output] to [On] to display the waveform monitor on the respective monitoring devices.
  • Alternatively, you can press an assignable button set to [WFM: VIDEO] (optional viewfinder only), [WFM: MON.+HDMI] (external monitors only), or [Waveform Monitor] (all monitoring devices at once).
  • You can use the MENU/EVF  [Assist. Functions] ( [Waveform Monitor]  [Position] setting to select the position of the waveform monitor on the screen (left or right side).


Configuring the Waveform Monitor

  1. Open the waveform monitor's [Type] submenu.
    MENU/EVF  [Assist. Functions] ( [Waveform Monitor]  [Type]
  2. Select the desired option and then press SET.
    • If you selected [Select Line], continue the procedure to set the Y coordinate of the line you wish to display.
      ​Otherwise, skip to step 5 to change the gain.
  3. From the same submenu, select [Select Line] and then press SET.
  4. Enter the Y coordinate of the desired line using the keyboard screen.
    • While recording, when the vertical resolution (number of horizontal lines) is 1080, you can select a value between 0 and 1079 (1-line increments); when the vertical resolution is a value other than 1080, you can select a value between 0 and the <vertical resolution - 2> (2-line increments).
    • During playback, depending on the clip's resolution, you can select a value from one of the following ranges.
      0 to 1079 (1-line increments)
      0 to 2158 (2-line increments)
      0 to 3138 (2-line increments)*
      * C700 FF C700 FF PL only.
  5. From the same submenu select [Gain] and then press SET.
  6. Select the desired amplification ratio and then press SET.
    • If you selected [1x], the rest of the procedure is not necessary. If you selected [2x], the display range of the waveform monitor's Y axis will be reduced by half. Continue the procedure to select the minimum luminance value (in %) shown on the Y axis.
  7. From the same submenu select [Y Position] and then press SET.
  8. Select the desired percentage and then press SET.
Options
[Line]: Sets the waveform monitor to line display mode.
[Line+Spot]: The waveform of the area in the red frame is displayed in red on top of the [Line] mode waveform.
[Select Line]: The selected horizontal line will be displayed along with its waveform.
[Field]: Sets the waveform monitor to field display mode.
[RGB]: Functions like an RGB parade scope.
[YPbPr]: Functions like a YPbPr parade scope.

 NOTES
  • The waveform monitor will not be affected even if a LUT is applied to the video output.
  • The waveform monitor cannot be displayed while magnification is activated.
  • If the [Knee] settings in the custom picture file were changed, a horizontal line will appear on the waveform monitor indicating the luminance (Y) level corresponding to the knee point.

Rate this Article
Was this article helpful?
Yes, This document is helpful
No, This document needs a clearer explanation
 
Please provide your comments