How to adjust the SNMP settings. (MF6595cx/MF6595/MF6590/MF6540 Only)

Article ID: ART101056 | Date published: 05/11/2015 | Date last updated: 08/15/2015
 

Solution

SNMP (Simple Network Management Protocol) helps monitor the state of the machine and collects information on it.
The default setting is <AUTO> for <USE SNMP> and <161> for <PORT NO.>.
The following two items can be set:
  • <COMMUNITY NAME>:
Sets the SNMP community name. You can specify up to two community names. The default setting is <public> for COMMUNITY NAME 1.
  • <SNMP WRITABLE>:
Enables the computers on the network to access the machine and modify its settings if this item is activated. You can specify this setting for each community separately. The default setting is <ON> for SNMP WRITABLE 1 and <OFF> for SNMP WRITABLE 2.
1. Press [Additional Functions].

2. Press [<-] or [+>] to select <SYSTEM SETTINGS>, then press [OK].

3. Press [<-] or [+>] to select <NETWORK SETTINGS>, then press [OK].

4. Press [<-] or [+>] to select <SNMP SETTINGS>, then press [OK].

5. Press [<-] or [+>] to select <USE SNMP>, then press [OK].6. Press [<-] or [+>] to select <ON> or <OFF>, then press [OK].

  • <ON>: When you set or browse each item of the machine with utility that uses SNMP to obtain information.
  • <OFF>: When you do not use an SNMP utility. Skip to step 8.
note:
  • If you want to use a Canon printer driver or utility, select <ON> for <USE SNMP> and <DEDICATED PORT>.
  • You can restrict the IP addresses of computers on which items can be set or browsed. If you restrict the IP addresses, it is not possible to use the Remote UI to set or browse detailed information on computers other than those whose IP addresses are allowed, even if <USE SNMP> and <DEDICATED PORT> are <ON>.

7. Use [<-], [+>], or the numeric keys to change the port number, then press [OK].

8. Press [<-] or [+>] to select <COMMUNITY NAME 1>, then press [OK].

9. Use the numeric keys to enter the desired community name other than ?public,? then press [OK].

10. If you need to specify <COMMUNITY NAME 2>, press [<-] or [+>] to select <COMMUNITY NAME 2>, then press [OK].

If you need not specify <COMMUNITY NAME 2>, skip to step 12.
11. Use the numeric keys to enter the desired community name, then press [OK].

12. Press [<-] or [+>] to select <SNMP WRITABLE 1>, then press [OK].

13. Press [<-] or [+>] to select <ON>, then press [OK].14. Press [<-] or [+>] to select <SNMP WRITABLE 2>, then press [OK].

If you need not specify <SNMP WRITABLE 2>, skip to step 16.
15. Press [<-] or [+>] to select <ON>, then press [OK].

16. Press [Stop] to return to the standby mode.

17. Restart the machine.