Correcting Gradation

Solution

Correcting Gradation

You can recalibrate the machine when you notice irregularities in the color of the copies or prints, such as when copies turn out to be different from the original in gradation, density, or color.

There are three adjustments you can perform, please make a choice below for detailed instructions:

Full Correction

This is a precise recalibration for the machine's gradation, density, and color settings. The procedure involves making test prints and placing them on the platen glass for scanning. Once this is complete, the machine automatically corrects the irregularities.

note:
  • Make sure that you place the test prints properly. Accurate recalibrations of the gradation, density, and color settings of the machine cannot be made if the test prints are not scanned correctly.
  • Two test prints are output by the machine during this adjustment. Make sure that a sufficient supply of LTR or A4 paper is loaded into the machine before starting this procedure.
  • Test prints are not counted as part of the copy or print total page counts.
  • It takes approximately five minutes to perform the Full Correction.
  • For an accurate adjustment, do not use colored paper, transparencies, or labels. It is recommended that you use plain white paper when performing a Full Correction.
  • If you set <Color> in <Paper Type> of <Paper Settings>, Full Correction cannot be performed. To perform a Full Correction, set <Paper Type> other than <Color>.

1. Press [ (Main Menu).

2. Press the right Any key to select <Additional Func.>.

3. Use [ ] , [ ] or (Scroll Wheel) to select <Adjustment/Cleaning>, then press [OK].

4. Use [ ] , [ ] or (Scroll Wheel) to select <Auto Gradation Correction>, then press [OK].

5. Use [ ] , [ ] or (Scroll Wheel) to select <Full Correction>, then press [OK].

6. Confirm that <Test Print 1> is displayed, then press [OK].

If you set <Color> in <Paper Type> of <Paper Settings>, an error message will appear. If this is the case, follow the instructions below.

(1) Press the right Any key to select <Done> and return to the screen in step 5.

(2) Load LTR or A4 plain paper into the stack bypass tray and set the paper size and type.

(3) Use [ ] , [ ] or (Scroll Wheel) to select <Full Correction>.

note:

If the paper for the test print is not loaded in a paper source, a message asks you to load the appropriate paper. In this case, load the appropriate paper in a paper source.

7. Place the first test print on the platen glass.

Place the test print face down on the platen glass, with the black bands along the top left edge of the platen glass.

Stack approximately 20 sheets of blank paper on top of the test print for a more precise gradation correction.

8. Confirm that a screen shown left appears on the display, then press [OK].

9. Confirm that <Test Print 2> is displayed, then press [OK].

If you set <Color> in <Paper Type> of <Paper Settings>, an error message will appear. If this is the case, follow the instructions below.

(1) Press the right Any key to select <Done> and return to the screen in step 5.

(2) Load LTR or A4 plain paper into the stack bypass tray and set the paper size and type.

(3) Use [ ] , [ ] or (Scroll Wheel) to select <Full Correction>.

10. Place the second test print on the platen glass.

Place the test print face down on the platen glass, with the black bands along the top left edge of the platen glass.

Stack approximately 20 sheets of blank paper on top of the test print for a more precise gradation correction.

11. Confirm that a screen shown left appears on the display, then press [OK].

12. Press [ (Main Menu) to return to the Main Menu screen.

Top

Quick Correction

This is a quick and simple adjustment that is made to the gradation, density, and color settings of the machine. Recalibrations are made ly without outputting any test prints.

note:

It takes approximately two and a half minutes to perform the Quick Correction.

1. Press [ (Main Menu).

2. Press the right Any key to select <Additional Func.>.

3. Use [ ] , [ ] or (Scroll Wheel) to select <Adjustment/Cleaning>, then press [OK].

4. Use [ ] , [ ] or (Scroll Wheel) to select <Auto Gradation Correction>, then press [OK].

5. Use [ ] , [ ] or (Scroll Wheel) to select <Quick Correction>, then press [OK].

6. Confirm that <Start> is displayed, then press [OK].

7. Press [ (Main Menu) to return to the Main Menu screen.

Top

Copy Image Correction

This is a precise copy image recalibration for the machine's gradation, density, and color settings. The procedure involves making a test print and placing it on the platen glass for scanning. Once this is complete, the machine automatically corrects the irregularities.

note:
  • For an accurate adjustment, do not use colored paper, transparencies, or labels. It is recommended that you use plain white paper when performing Copy Image Correction.
  • If you set <Color> in <Paper Type> of <Paper Settings>, Copy Image Correction cannot be performed. To perform a Copy Image Correction, set <Paper Type> other than <Color>. For instructions on how to set the paper type, see "."
  • Make sure that you place the test prints properly. Accurate recalibrations of the gradation, density, and color settings of the machine cannot be made if the test prints are not scanned correctly.
  • A test print is output by the machine during this adjustment. Make sure that a sufficient supply of LTR or A4 paper is loaded into the machine before starting this procedure.
  • Test prints are not counted as part of the copy or print total page counts.
  • It takes approximately two and a half minutes to perform the Copy Image Correction.

1. Press [ (Main Menu).

2. Press the right Any key to select <Additional Func.>.

3. Use [ ] , [ ] or (Scroll Wheel) to select <Adjustment/Cleaning>, then press [OK].

4. Use [ ] , [ ] or (Scroll Wheel) to select <Auto Gradation Correction>, then press [OK].

5. Use [ ] , [ ] or (Scroll Wheel) to select <Copy Image Correction>, then press [OK].

6. Confirm that <Test Print 1> is displayed, then press [OK].

If you set <Color> in <Paper Type> of <Paper Settings>, an error message will appear. If this is the case, follow the instructions below.

(1) Press the right Any key to select <Done> and return to the screen in step 5.

(2) Load LTR or A4 plain paper into the stack bypass tray and set the paper size and type.

(3) Use [ ] , [ ] or (Scroll Wheel) to select <Copy Image Correction>.

note:

If the paper for the test print is not loaded in a paper source, a message asks you to load the appropriate paper. In this case, load the appropriate paper in a paper source.

7. Place the test print on the platen glass.

Place the test print face down on the platen glass, with the black bands along the top left edge of the platen glass.

Stack approximately 20 sheets of blank paper on top of the test print for a more precise gradation correction.

8. Confirm that a screen shown left appears on the display, then press [OK].

9. Press [ (Main Menu) to return to the Main Menu screen.