T90 : How to select and use the metering modes.

Article ID: ART121704 | Date published: 05/12/2015 | Date last updated: 08/17/2015
 

Description

T90 : How to select and use the metering modes.

Solution

While pressing the metering mode selector, turn the electronic input dial until the desired metering mode appears on the display panel.
Center Weighted - The mode is the normal setting position used for general photography and is recommended especially for AE photography
Partial Metering - With this metering system the AE lock mechanism is on as long as the shutter button is being pressed.
  1. Put the main subject in the cent of the viewfinder so that the partial metering mark covers it.
  2. Press the shutter button halfway and compose the picture. A red "*" mark (AE lock LED) will then appear in the viewfinder
Spot Metering - Only one point is measured in the viewfinder.
  1. Put the main subject in the center of the viewfinder so that the spot metering mark covers it.
  2. Press the spot metering button.
  3. When the spot metering button is pressed the shutter speed and aperture are displayed at the bottom of the viewfinder.

SIMS Doc Id

0

Rate this Article
Was this article helpful?
Yes, This document is helpful
No, This document needs a clearer explanation
 
Please provide your comments