Article ID: ART179703 |
| |
Date published: 04/27/2021 |
| |
Date last updated: 04/27/2021 |
Description
When rollers are worn, paper jams and double feeds tend to occur. You can replace the rollers (Pickup Roller, Feed Roller, and Separation Roller) according to the following procedure.
The exchange roller kit is a consumable item and not included with the scanner. Purchase an exchange roller kit separately: 1732C001.
Solution
- Pull the Open Button, and pull the Right Maintenance Cover open to the right.

- Remove the Roller Cover.


As shown in the figure, release hook (1) (left button) and hook (2) (right top toward the back) of the roller cover, and then lift up the cover. This will allow you to remove the cover.
- Push up the Separation OFF Lever in the direction of the arrow.

- While pushing up the Separation OFF Lever, pinch the edge of the Feed Roller and the fixing lever, and then remove the roller.


If the Feed Roller (Separation Roller) is not removed easily because of the fixing lever position, turn the Feed Roller in clockwise direction by hand.

- PInch the Separation Roller at the rim and the fixing lever, and then remove it.

- Pinch the Pickup Roller at the rim and the fixing lever, and then remove it.


If the Pickup ROller is not removed easily because of the fixing lever position, turn the Pickup Roller by hand.
- Attach the new Pickup Roller. Align the notch on the roller axis with the hole of the roller.


Push down on the roller until it clicks into place.
- Attach the new Separation Roller. Align the notch on the roller axis with the hole of the roller.


Push down on the roller until it clicks into place.
- Attach the new Feed Roller. Align the notch on the roller axis with the hole on the roller.


Push down on the roller until it clicks into place.
- Adjust the Adjustment Dial to 6.
- Replace the Roller Cover.