Description

Clean the scanner on a regular basis, as described below, to maintain peak scanning quality.

 CAUTION
  • When cleaning the scanner, turn OFF the power button and disconnect the power cord from the power outlet.
  • Do not use spray cleaners to clean the scanner. Precision mechanisms, such as the light source, may get wet and cause a malfunction.
  • Never use paint thinner, alcohol, or other organic solvents to clean the scanner. The exterior of the scanner may become deformed, discolored, or melted. It may also cause a fire or electric shock.

Solution

Cleaning the Outside of the Scanner

To clean the outside of the scanner, wipe off any dirt with a cloth that has been dampened with water and thoroughly wrung out, and then wipe the scanner dry with a clean dry cloth.

 

Cleaning the Inside of the Scanner

Dust or paper particles inside the scanner may cause lines or smudges to appear on the scanned images. Use compressed air to periodically clean dust and paper particles from the document feed opening and the inside of the scanner. After finishing a large scanning job, turn OFF the scanner and then clean out any paper particles remaining inside the scanner.

 

Cleaning the Sensor Glass and the Rollers

If scanned images contain streaks, or if the scanned documents become dirty, the sensor glass or rollers inside the scanner may be dirty. Clean them periodically.
  1. Pull the OPEN lever and pull open the front unit toward you.

     
  2. Use compressed air to remove dust and paper particles from the inside of the scanner.
     
  3. Wipe any dirt off the scanning glass.
    Wipe any dirt off the scanning glass with a cloth that has been dampened with water and thoroughly wrung out, and then wipe the glass dry with a clean, dry soft cloth.

     CAUTION
    Do not spray water or neutral detergent directly on the scanner. Precision mechanisms, such as the light source, may get wet, and cause a malfunction.

    - Scratches on the sensor glass may cause marks on the images, as well as feeding errors.
    - Take care to ensure the anti-static brush in the front unit does not become deformed.

     
  4. Clean the rollers.
    Clean the rollers while turning them. 
    Wipe the rollers with a cloth that has been dampened with water and thoroughly wrung out, and then use a clean, dry soft cloth to wipe away any moisture.

     
  5. Remove the retard roller and feed roller.

    Remove the retard roller and the feed roller from the scanner to clean them, and be sure to reattach them to the scanner when cleaning is finished.
     
  6. Wipe the removed rollers with a cloth that has been dampened with water and thoroughly wrung out.

     
  7. Reattach the retard roller and feeding roller.
     
  8. Close the front unit by gently pushing it up on both sides until it clicks into place. Make sure that the front unit is completely closed by pushing until you hear a click.